1.
Med Phys ; 38(11): 5969-79, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22047361

RESUMO

PURPOSE: To quantify the improvement in megavoltage cone beam computed tomography (MVCBCT) image quality enabled by the combination of a 4.2 MV imaging beam line (IBL) with a carbon electron target and a detector system equipped with a novel sintered pixelated array (SPA) of translucent Gd(2)O(2)S ceramic scintillator. Clinical MVCBCT images are traditionally acquired with the same 6 MV treatment beam line (TBL) that is used for cancer treatment, a standard amorphous Si (a-Si) flat panel imager, and the Kodak Lanex Fast-B (LFB) scintillator. The IBL produces a greater fluence of keV-range photons than the TBL, to which the detector response is more optimal, and the SPA is a more efficient scintillator than the LFB. METHODS: A prototype IBL + SPA system was installed on a Siemens Oncor linear accelerator equipped with the MVision(TM) image guided radiation therapy (IGRT) system. A SPA strip consisting of four neighboring tiles and measuring 40 cm by 10.96 cm in the crossplane and inplane directions, respectively, was installed in the flat panel imager. Head- and pelvis-sized phantom images were acquired at doses ranging from 3 to 60 cGy with three MVCBCT configurations: TBL + LFB, IBL + LFB, and IBL + SPA. Phantom image quality at each dose was quantified using the contrast-to-noise ratio (CNR) and modulation transfer function (MTF) metrics. Head and neck, thoracic, and pelvic (prostate) cancer patients were imaged with the three imaging system configurations at multiple doses ranging from 3 to 15 cGy. The systems were assessed qualitatively from the patient image data. RESULTS: For head and neck and pelvis-sized phantom images, imaging doses of 3 cGy or greater, and relative electron densities of 1.09 and 1.48, the CNR average improvement factors for imaging system change of TBL + LFB to IBL + LFB, IBL + LFB to IBL + SPA, and TBL + LFB to IBL + SPA were 1.63 (p < 10(- 8)), 1.64 (p < 10(- 13)), 2.66 (p < 10(- 9)), respectively. For all imaging doses, soft tissue contrast was more easily differentiated on IBL + SPA head and neck and pelvic images than TBL + LFB and IBL + LFB. IBL + SPA thoracic images were comparable to IBL + LFB images, but less noisy than TBL + LFB images at all imaging doses considered. The mean MTFs over all imaging doses were comparable, at within 3%, for all imaging system configurations for both the head- and pelvis-sized phantoms. CONCLUSIONS: Since CNR scales with the square root of imaging dose, changing from TBL + LFB to IBL + LFB and IBL + LFB to IBL + SPA reduces the imaging dose required to obtain a given CNR by factors of 0.38 and 0.37, respectively. MTFs were comparable between imaging system configurations. IBL + SPA patient image quality was always better than that of the TBL + LFB system and as good as or better than that of the IBL + LFB system, for a given dose.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Intensificação de Imagem Radiográfica/instrumentação , Humanos , Masculino , Neoplasias/diagnóstico por imagem
2.
Med Phys ; 37(4): 1737-41, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20443494

RESUMO

PURPOSE: To use an imaging beam line (IBL) to obtain the first megavoltage cone-beam computed tomography (MV CBCT) images of patients with a low atomic number (Z) target, and to compare these images to those taken of the same patients with the 6 MV flattened beam from the treatment beam line (TBL). METHODS: The IBL, which produces a 4.2 MV unflattened beam from a carbon target, was installed on a linear accelerator in use for radiotherapy. Provision was made for switching between the IBL and TBL for imaging the same patient with beams from the low-Z and high-Z targets. Dose was quoted as monitor units times the dose per monitor unit for the standard calibration geometry. Images were acquired with institutional approval and patient consent with both the IBL and TBL on a series of 23 patients undergoing radiotherapy. Patients were imaged daily to weekly and aligned to the planning CT using the images. Doses were reduced over the course of treatment to determine the minimum doses required for alignment. Images were assessed offline. RESULTS: IBL MV CBCT images of prostate, head and neck, lung, and abdomen showed improvement in soft tissue contrast for the same dose as the TBL images. Bony anatomy, air cavities, and fiducial markers were sharper. CBCT with a dose of 1 cGy was sufficient for alignment of prostate and head and neck patients based on bony anatomy or implanted gold seeds, 2-4 cGy for lung, abdomen, and pelvis. Photon scatter in the patient had minimal effect on image quality. The metallic hip prosthesis in one patient showed reduced artifacts compared to diagnostic CT. CONCLUSIONS: The IBL has the advantage of improved image quality at the same dose, or reduced dose for the same image quality, over the TBL.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Radioterapia/métodos , Osso e Ossos/patologia , Calibragem , Carbono/química , Desenho de Equipamento , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Neoplasias Pulmonares/patologia , Masculino , Neoplasias Pélvicas/patologia , Fótons , Neoplasias da Próstata/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Espalhamento de Radiação
3.
J Appl Clin Med Phys ; 10(3): 37-48, 2009 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-19692984

RESUMO

To measure and compare the contrast to noise ratio (CNR) as a function of dose for the CBCTs produced by the mega-voltage (MV) imaging beam line (IBL) and the treatment beam line (TBL), and to compare the dose to target and various critical structures of pediatric patients for the IBL CBCT versus standard TBL orthogonal port films. Two Siemens Oncor linear accelerators were modified at our institution such that the MV-CBCT would operate under an investigational IBL rather than the standard 6MV TBL. Prior to the modification, several CBCTs of an electron density phantom were acquired with the TBL at various dose values. After the modification, another set of CBCTs of the electron density phantom were acquired for various doses using the IBL. The Contrast to Noise Ratio (CNR) for each tissue equivalent insert was calculated. In addition, a dosimetric study of pediatric patients was conducted comparing the 1 cGy IBL CBCT and conventional TBL orthogonal pair port films. The CNR for eight tissue equivalent inserts at five different dose settings for each type of CBCT was measured. The CNR of the muscle insert was 0.8 for a 5 cGy TBL CBCT, 1.1 for a 1.5 cGy IBL CBCT and 2.8 for a conventional CT. The CNR of the trabecular bone insert was 2.9 for a 5 cGy TBL CBCT, 5.5 for a 1.5 cGy IBL CBCT and 14.8 for a conventional CT. The IBL CBCT delivered approximately one-fourth the dose to the target and critical structures of the patients as compared to the TBL orthogonal pair port films. The IBL CBCT improves image quality while simultaneously reducing the dose to the patient as compared to the TBL CBCT. A 1 cGy IBL CBCT, which is used for boney anatomy localization, delivers one-fourth the dose as compared to conventional ortho-pair films.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Imagens de Fantasmas , Humanos , Aceleradores de Partículas
4.
IEEE Trans Med Imaging ; 27(12): 1791-810, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19033095

RESUMO

Quantitative reconstruction of cone beam X-ray computed tomography (CT) datasets requires accurate modeling of scatter, beam-hardening, beam profile, and detector response. Typically, commercial imaging systems use fast empirical corrections that are designed to reduce visible artifacts due to incomplete modeling of the image formation process. In contrast, Monte Carlo (MC) methods are much more accurate but are relatively slow. Scatter kernel superposition (SKS) methods offer a balance between accuracy and computational practicality. We show how a single SKS algorithm can be employed to correct both kilovoltage (kV) energy (diagnostic) and megavoltage (MV) energy (treatment) X-ray images. Using MC models of kV and MV imaging systems, we map intensities recorded on an amorphous silicon flat panel detector to water-equivalent thicknesses (WETs). Scattergrams are derived from acquired projection images using scatter kernels indexed by the local WET values and are then iteratively refined using a scatter magnitude bounding scheme that allows the algorithm to accommodate the very high scatter-to-primary ratios encountered in kV imaging. The algorithm recovers radiological thicknesses to within 9% of the true value at both kV and megavolt energies. Nonuniformity in CT reconstructions of homogeneous phantoms is reduced by an average of 76% over a wide range of beam energies and phantom geometries.


Assuntos
Algoritmos , Tomografia Computadorizada de Feixe Cônico/métodos , Espalhamento de Radiação , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Radiografia Abdominal/métodos , Raios X
5.
Med Phys ; 35(10): 4513-23, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18975698

RESUMO

The accurate delivery of external beam radiation therapy is often facilitated through the implantation of radio-opaque fiducial markers (gold seeds). Before the delivery of each treatment fraction, seed positions can be determined via low dose volumetric imaging. By registering these seed locations with the corresponding locations in the previously acquired treatment planning computed tomographic (CT) scan, it is possible to adjust the patient position so that seed displacement is accommodated. The authors present an unsupervised automatic algorithm that identifies seeds in both planning and pretreatment images and subsequently determines a rigid geometric transformation between the two sets. The algorithm is applied to the imaging series of ten prostate cancer patients. Each test series is comprised of a single multislice planning CT and multiple megavoltage conebeam (MVCB) images. Each MVCB dataset is obtained immediately prior to a subsequent treatment session. Seed locations were determined to within 1 mm with an accuracy of 97 +/- 6.1% for datasets obtained by application of a mean imaging dose of 3.5 cGy per study. False positives occurred in three separate instances, but only when datasets were obtained at imaging doses too low to enable fiducial resolution by a human operator, or when the prostate gland had undergone large displacement or significant deformation. The registration procedure requires under nine seconds of computation time on a typical contemporary computer workstation.


Assuntos
Imageamento Tridimensional/métodos , Reconhecimento Automatizado de Padrão/métodos , Próteses e Implantes , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radioterapia Conformacional/instrumentação , Técnica de Subtração , Tomografia Computadorizada por Raios X/instrumentação , Algoritmos , Inteligência Artificial , Humanos , Intensificação de Imagem Radiográfica/métodos , Radioterapia Assistida por Computador/instrumentação , Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
6.
Med Phys ; 35(6): 2452-62, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18649478

RESUMO

We describe a focused beam-stop array (BSA) for the measurement of object scatter in imaging systems that utilize x-ray beams in the megavoltage (MV) energy range. The BSA consists of 64 doubly truncated tungsten cone elements of 0.5 cm maximum diameter that are arranged in a regular array on an acrylic slab. The BSA is placed in the accessory tray of a medical linear accelerator at a distance of approximately 50 cm from the focal spot. We derive an expression that allows us to estimate the scatter in an image taken without the array present, given image values in a second image with the array in place. The presence of the array reduces fluence incident on the imaged object. This leads to an object-dependent underestimation bias in the scatter measurements. We apply corrections in order to address this issue. We compare estimates of the flat panel detector response to scatter obtained using the BSA to those derived from Monte Carlo simulations. We find that the two estimates agree to within 10% in terms of RMS error for 30 cm x 30 cm water slabs in the thickness range of 10-30 cm. Larger errors in the scatter estimates are encountered for thinner objects, probably owing to extrafocal radiation sources. However, RMS errors in the estimates of primary images are no more than 5% for water slab thicknesses in the range of 1-30 cm. The BSA scatter estimates are also used to correct cone beam tomographic projections. Maximum deviations of central profiles of uniform water phantoms are reduced from 193 to 19 HU after application of corrections for scatter, beam hardening, and lateral truncation that are based on the BSA-derived scatter estimate. The same corrections remove the typical cupping artifact from both phantom and patient images. The BSA proves to be a useful tool for quantifying and removing image scatter, as well as for validating models of MV imaging systems.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Difração de Raios X , Simulação por Computador , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Radiografia Abdominal , Água/química
7.
Med Phys ; 35(12): 5777-86, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19175135

RESUMO

Megavoltage cone beam computed tomography (MVCBCT) is routinely used for visualizing anatomical structures and implanted fiducials for patient positioning in radiotherapy. MVCBCT using a 6 MV treatment beam with high atomic number (Z) target and flattening filter in the beamline, as done conventionally, has lower image quality than can be achieved with a MV beam due to heavy filtration of the low-energy bremsstrahlung. The unflattened beam of a low Z target has an abundance of diagnostic energy photons, detected with modern flat panel detectors with much higher efficiency given the same dose to the patient. This principle guided the development of a new megavoltage imaging beamline (IBL) for a commercial radiotherapy linear accelerator. A carbon target was placed in one of the electron primary scattering foil slots on the target-foil slide. A PROM on a function controller board was programed to put the carbon target in place for MVCBCT. A low accelerating potential of 4.2 MV was used for the IBL to restrict leakage of primary electrons through the target such that dose from x rays dominated the signal in the monitor chamber and the patient surface dose. Results from phantom and cadaver images demonstrated that the IBL had much improved image quality over the treatment beam. For similar imaging dose, the IBL improved the contrast-to-noise ratio by as much as a factor of 3 in soft tissue over that of the treatment beam. The IBL increased the spatial resolution by about a factor of 2, allowing the visualization of finer anatomical details. Images of the cadaver contained useful information with doses as low as 1 cGy. The IBL may be installed on certain models of linear accelerators without mechanical modification and results in significant improvement in the image quality with the same dose, or images of the same quality with less than one-third of the dose.


Assuntos
Carbono/química , Tomografia Computadorizada de Feixe Cônico/métodos , Radioterapia/métodos , Diagnóstico por Imagem/métodos , Relação Dose-Resposta à Radiação , Elétrons , Desenho de Equipamento , Humanos , Método de Monte Carlo , Aceleradores de Partículas , Imagens de Fantasmas , Fótons , Espalhamento de Radiação , Aço Inoxidável , Raios X